HOW TO CORRECTLY SIZE THE ATEX EXPLOSION-PROOF VFD (IN KW) FOR AN LNG SUBMERGED PUMP DELIVERING 30 M3/H WITH A HEAD OF 150 METERS?
Understanding the Role of VFDs in LNG Applications
Variable Frequency Drives (VFDs) are crucial components in various industrial applications, particularly in the oil and gas sector. In the context of Liquefied Natural Gas (LNG), where safety and efficiency are paramount, selecting the correct size of an ATEX explosion-proof VFD becomes a significant task.
Key Parameters for Sizing
When sizing a VFD for an LNG submerged pump that delivers 30 cubic meters per hour (m3/h) against a head of 150 meters, several key parameters need to be considered:
- Flow Rate: The desired flow rate, in this case, 30 m3/h, is essential as it determines the operational capacity required from the pump.
- Head Pressure: The head of 150 meters indicates the height to which the liquid must be pumped, influencing the necessary power output of the system.
- Fluid Properties: LNG has distinct properties that can affect pump performance, including viscosity and density, which must be accounted for during calculations.
- Efficiency Factors: Efficiency ratings of both the pump and the VFD will lead to variations in the required input power, necessitating adjustments to the initial calculations.
Calculating Hydraulic Power Requirement
The hydraulic power requirement can be calculated using the following formula:
Phydraulic = (Q x H x ρ x g) / η
Where:
- Phydraulic: Hydraulic power in watts (W)
- Q: Flow rate in cubic meters per second (m3/s)
- H: Head in meters (m)
- ρ: Density of LNG in kilograms per cubic meter (kg/m3)
- g: Acceleration due to gravity (approximately 9.81 m/s2)
- η: Pump efficiency (expressed as a decimal)
Example Calculation
To proceed with the calculation, one must first convert the flow rate into cubic meters per second:
30 m3/h = 30 / 3600 = 0.00833 m3/s
Assuming a density of LNG at approximately 450 kg/m3 and a typical pump efficiency of 0.8, the hydraulic power can be calculated:
Phydraulic = (0.00833 x 150 x 450 x 9.81) / 0.8
Upon performing this calculation, one would arrive at a value approximately equal to 51.48 kW.
Accounting for VFD and Motor Efficiency
The next step involves accounting for the VFD's efficiency, often estimated around 95%. The total power requirement can be then calculated as:
Ptotal = Phydraulic / (ηVFD x ηmotor)
Assuming a motor efficiency of 90%, we can substitute the values:
Ptotal = 51.48 / (0.95 x 0.90)
This results in a total power requirement nearing 60.07 kW.
Incorporating Safety Margins
In hazardous environments, particularly those involving LNG, adding a safety margin is prudent. Typically, a 10-20% margin should suffice, leading to:
- With 10% Margin: 60.07 kW x 1.10 = 66.08 kW
- With 20% Margin: 60.07 kW x 1.20 = 72.08 kW
Thus, the final selection of the VFD should be made within the range of 66-72 kW to ensure operational reliability while maintaining compliance with ATEX standards.
Conclusion on Selection
After determining the appropriate power requirements, it is critical to choose an ATEX certified explosion-proof VFD that meets these specifications. Brands such as CRYO-TECH provide solutions specifically designed for demanding applications like LNG pumping, ensuring safety and performance in explosive atmospheres.